R&S®TS712x Shielded RF Test Chamber
Reliable RF tests on devices with radio interface
Applications
- Use in production, service, R & D and quality control
- Tests on mobile phones and devices with a radio interface such as Bluetooth®, WiMAX, WLAN, ISM and RFID
Characteristics
- High shielding effectiveness
- Low reflection due to use of absorbent material
- Integrated RF connectors and filter feedthroughs
- Pneumatically supported opening and closing
- Rugged design for long service life
Options
- Various sizes
- R&S® TS7121 for small devices and modules
- R&S® TS7123 for larger DUTs
- Manual version with handle
- Integration of different types of antenna couplers, e.g. GSM, WLAN, Bluetooth® and ISM
- Elevated cover, e.g. for integrating CCD cameras or keyboard stimulators
Mechanical Design
The actual RF chamber is located above the pneumatic chamber. On the RF chamber rear panel, four RF feedthroughs are provided for connecting antenna couplers or DUT RF interfaces. Customer-specific antenna couplers or antenna couplers from Rohde & Schwarz can be attached as required to the side panels or the bottom panel of the RF chamber.
The interior of the RF chamber may optionally be lined with absorbent material, which attenuates high-frequency electromagnetic waves and thus ensures reproducible and stable measurements. The absorbent material also works in the low-frequency audio range, where it effectively reduces ambient sound.
The DUT is slid into the RF chamber through the chamber window on the slide-in unit by pneumatic or manual control. The supporting plate which holds the DUT mount or the DUT itself contains a centering pin and rests on a stable guiding mechanism. This ensures reproducible positioning of the DUT or application-specific DUT mounts.
GSM/CDMA2000®/WCDMA and Bluetooth® antenna couplers in the range 800 MHz to 2.4 GHz are currently available; the couplers can be attached to the side panels or the bottom panel. Moreover, ISM couplers for frequencies < 1 GHz and WLAN antenna couplers for 2.4 GHz to 5.8 GHz are available that can be adapted for use with this RF test chamber.
The RF chamber is sealed by means of a milled cover, which is fastened in place with easy-to-lock tension levers. Optionally, elevated covers are available that provide sufficient room for the integration of further test equipment such as CCD cameras or keyboard stimulators.
The R&S® TS7121M manual version is equipped with a handle that allows easy closing and locking of the RF chamber. This version is mainly intended for use in service and development. A lot of customers use this version for production, too. The automatic and the manual versions of the RF shielding chamber have the same basic design, ensuring the same test functionality in both.